AutoTune™ User Guide
4.9. External Voice Modulation
The purpose of this procedure is to test the ability of an external microphone attached to
the radio to effectively transfer the received signal.
Table 4-22. Analyzer Configuration for External Voice Modulation test
4.9.1. Alignment
No alignment is needed.
4.9.2. Test
The radio is placed into Test Mode at the lowest TX Test Frequency. The analyzer is
setup as specified in this section’s Analyzer Configuration table. The analyzer generates
a 1 kHz signal at 800 mV into the radio’s external microphone accessory port via the
radio test set. The radio is commanded to transmit and the resulting deviation level is
then measured by the analyzer. The measured deviation is compared against test limits
and the final results are written to the log file.
Pass or Fail. Deviation within Min Limit, Max Limit
Measured modulation deviation level
Minimum Limit (inclusive) for Deviation to Pass
Maximum Limit (inclusive) for Deviation to Pass
Table 4-23. External Voice Modulation test results