AutoTune™ User Guide
14
4.9. External Voice Modulation
The purpose of this procedure is to test the ability of an external microphone attached to
the radio to effectively transfer the received signal.
RF Control
Port
Frequency
Modulation
Attenuation
Monitor
RF IN/OUT
Test Frequency
FM
40 dB
Table 4-22. Analyzer Configuration for External Voice Modulation test
4.9.1. Alignment
No alignment is needed.
4.9.2. Test
The radio is placed into Test Mode at the lowest TX Test Frequency. The analyzer is
setup as specified in this section’s Analyzer Configuration table. The analyzer generates
a 1 kHz signal at 800 mV into the radio’s external microphone accessory port via the
radio test set. The radio is commanded to transmit and the resulting deviation level is
then measured by the analyzer. The measured deviation is compared against test limits
and the final results are written to the log file.
Name
Description
Result
Pass or Fail. Deviation within Min Limit, Max Limit
Frequency
Test Frequency
Deviation
Measured modulation deviation level
Min Limit
Minimum Limit (inclusive) for Deviation to Pass
Max Limit
Maximum Limit (inclusive) for Deviation to Pass
Table 4-23. External Voice Modulation test results