25
6.5. Sensitivity (SINAD)
Note: Motorola APXMobile High Power models are not supported for this test.
This is a test only; there is no alignment.
RF Control
Port
Frequency
Modulation
Level
Generate
RF IN/OUT
Test Freq
FM, 1 kHz @ 3kHz deviation
-50 dBm
Table 6-13. Analyzer Configuration for Sensitivity (SINAD) test
6.5.1. Alignment
No alignment is needed.
6.5.2. Test
The analyzer is setup as specified in this section’s Analyzer Configuration table. The
radio is placed into Test Mode at the lowest RX Test Frequency. The radio audio output
level is tested and if insufficient to measure SINAD the volume is increased until
sufficient to measure SINAD. The output level of the analyzer is then adjusted until the
radio audio signal’s SINAD level measures about 12 dB. The current analyzer output
level is then compared against test limits. The final results are written to the log file.
Dual-Band: This test is performed for the lowest RX Test Frequency in each band.
Name
Description
Result
Pass or Fail. Sensitivity (SINAD) level within Max Limit
Frequency
Test Frequency
12dB SINAD
Analyzer output level at which the radio SINAD level measures 12 dB
Max Limit
Maximum Limit (inclusive) for Sensitivity (SINAD) to Pass
Table 6-14. Sensitivity (SINAD) test results
Page view 31