AutoTune™ User Guide
4.8. Digital Sensitivity (BER)
NOTE: This test requires an analyzer with P25 Conventional test mode capability.
The purpose of this procedure is to measure the radio receiver’s Bit Error Rate at a
given frequency. The TIA/EIA standard BER rate is 5%. This is a test only; there is no
alignment.
Framed 1011 Hz Pattern,
2.83 kHz deviation
Table 4-20. Analyzer Configuration for Digital Sensitivity (BER) test
4.8.1. Alignment
No alignment is needed.
4.8.2. Test
The analyzer is setup as specified in this section’s Analyzer Configuration table. The
radio is placed into Test Mode at the lowest RX Test Frequency, ready to receive a
C4FM-modulated signal from the analyzer. Once BER synchronization is detected, the
analyzer output level is decreased until a BER of 5% is measured. The analyzer output
level at 5% BER is compared against test limits and the final results are written to the
log file.
Pass or Fail. Digital Sensitivity (BER) output level within Max Limit
Analyzer output level at which the radio BER measures 5%
Maximum Limit (inclusive) for Digital Sensitivity (BER) to Pass
Table 4-21. Digital Sensitivity (BER) test results