7. Basic Troubleshooting
Symptom
Possible Cause(s)
Possible Solution(s)
Radio repeatedly fails
communication
initialization.
Serial link corruption
Retry communicating with the
radio after each of the following
steps:
Power cycle the radio.
Restart the analyzer.
Radio won’t power up.
Loose HKN6163_
cable connection.
Verify cable connection is OK.
Motorola CPS
Ignition Switch
setting.
Use Motorola CPS software to set
Radio Wide, Advanced, Ignition
Switch setting to “Blank”. This
setting lets radio power up for
testing without an ignition signal
present. Be sure to return this
setting to its original value when
testing completed.
Radio consistently fails TX
Power Out test and/or
alignment.
ASTRO 25 Mobile
CPS TX/Transmit
Power Level settings
limiting radio output
power.
Using ASTRO 25 Mobile CPS,
adjust Radio Configuration>Radio
Wide>TX/Transmit Power Level
settings to factory defaults. This
change lets radio output expected
power levels for correct AutoTune
TX Power Out testing and
alignment.
Deviation Balance test
following a Deviation
Balance alignment
occasionally fails at one or
more test frequencies.
Both XTL and XTS
series radios have
narrow “good” softpot
ranges. These radios
are designed such
that softpot settings
giving deviation
balance
measurements within
test limits are few,
likely one or two
softpot values.
Rerun the Deviation Balance
alignment.